PCI Peciment® 50
Repair mortar
for bridge construction and civil engineering work to ZTV-ING and maintenance guideline

Areas of application
- For concrete repair and new installation of bonded coverings and for the preventive and additional protection of concrete surfaces on bridges or comparable civil engineering construction to ZTV-ING and maintenance guideline for the following applications:
PCC I: Surfaces exposed to traffic, subject to dynamical stress (e.g. under bridge coverings).
PCC II: Surfaces not exposed to traffic, subject to dynamical stress (e.g. undersides of bridges). - For layer thickness from 10 – 50 mm.
Concrete substitute of the PCI Peciment II system for the application PCC I and PCC II according to ZTV-ING.
Product features
- Included in the BASt list (German Transport Authorities) and the BAW list (German Federal Waterways Engineering and Research Institute) , PCI Peciment 50 is tested in accordance with ZTV-ING and quality controlled in accordance with TL/TP BE-PCC. Tested in compliance with ZTV-W LB 219.
- Ready to use when mixed with water.
- For layer thickness from 10 to 50 mm, to be applied on floors in one layer up to a thickness of 50 mm.
- Resistant to wear and aging, achieves high strength.
- Low shrinkage and crack-free curing with appropriate post-treatment, even in case of dynamical stress during the application and curing time.
- High resistance to carbonation, the corrosion-protective effect of the cement is retained.
- Resistant to frost and de-icing salt, multi-purpose use indoors and out.
- Impermeable to water.
- Permeable to water vapor.
- Resistant to bitumen.
Colors:
gray
Forms of delivery:
25-kg-bag
Consumption calculator
Your Result
Required quantity of dry mortar around
kg
corresponds
25-kg-bag
pieces
This consumption calculation included in the program contains approximate values based on experiences which might considerably vary upwards and also downwards depending on the structure of substrate, type of tiles, different profiles on the reverse sides, type of tiling tools, work method a.o. Calculations are therefore not allowed to be based on these values. In case of larger projects we recommend to assess the consumption by making a trial surface. Applications in the combined method (buttering-floating) increase the consumption by approx. 20 to 25%. In case of powder products the data relate to the consumption of dry powder for easier calculation of the material requirement.
YOUR DIRECT CONTACT
Downloads
Declaration of performance EN 1504-3 (R4)
Classification report EN 13501-1 (A2fl-s1)
Combined with product:
PCI Peciment® 50, PCI Pecihaft®
Classification report EN 13501-1 (A2 - s1, d0)
Combined with product:
PCI Peciment® 50, PCI Pecihaft®